Skip to content
24/7 Emergency Boiler Service, available day or night. Call 248-589-8220
Controls & safety devices

CSD-1 boiler testing & inspection support.

Annual CSD-1 testing of boiler controls and safety devices for commercial and industrial facilities in the Detroit area and across Southeast Michigan, by factory-trained technicians.

What CSD-1 is

A standard for boiler controls and safety devices

ASME CSD-1, Controls and Safety Devices for Automatically Fired Boilers, is a standard published by the American Society of Mechanical Engineers. It sets requirements for the controls and safety devices on automatically fired boilers, and for how those devices are installed, tested, maintained, and operated.

In practice, CSD-1 testing means confirming that the devices that protect a boiler, and the people around it, work as intended: operating pressure and temperature controls, fuel safety shut-off valves, flame safeguard controls, and low-water cutoff and level controls.

Whether a particular boiler falls under CSD-1, and how often it must be tested, depends on the equipment and the jurisdiction. Your insurance carrier or the authority having jurisdiction can confirm what applies to your boilers. We can keep the testing on schedule, and on a maintenance plan every visit is documented in a written report.

A D.J. Conley technician working in a mechanical room
What we do

CSD-1 testing from factory-trained technicians

  • Annual CSD-1 testing: as a single annual visit or as part of a preventive maintenance contract.
  • Safety and controls check: operating pressure and/or temperature controls, fuel safety shut-off valves, flame safeguard control, and level controls.
  • Combustion analysis: CO2/O2/NOx/SOx testing with certified equipment and printed results.
  • Controls work: calibration and replacement, and flame safety testing and replacement, when a device needs attention.
  • Inspection support: confined-space-qualified technicians open, clean, and prepare the pressure vessel for inspection.
  • Documented records: on a maintenance plan, a written service report after every visit, including combustion readings.
  • Boiler logs: keep your own day-to-day records with our Boiler Log, High Pressure Boiler Log, and Heating Boiler Log sheets (PDF).

Our service technicians take part in mandatory bi-weekly safety training, are OSHA 30 trained and certified, confined-space qualified, and complete Red Cross training every two years for First Aid, CPR & AED certification. Approved by the Avetta, BROWZ, and ISNetworld contractor management programs.

How it fits

One visit or a full program

A single annual visit

Your annual CSD-1 testing in one visit a year. You can add combustion analysis with printed results.

Part of a custom PM plan

CSD-1 testing can sit inside a preventive maintenance plan scoped to your equipment, with priority scheduling for facilities on a plan.

Repairs when something fails

If a test turns up a problem, we handle the repair: controls, burners, and pressure vessel work, plus 24/7 emergency service when a boiler is down.

CSD-1 questions

Common questions

What is ASME CSD-1?

ASME CSD-1, Controls and Safety Devices for Automatically Fired Boilers, is the American Society of Mechanical Engineers standard for the controls and safety devices on automatically fired boilers.

What do you check during CSD-1 testing?

CSD-1 testing focuses on the boiler’s controls and safety devices. Our safety check covers operating pressure and/or temperature controls, fuel safety shut-off valves, flame safeguard control, and level controls, and we can add combustion analysis with printed results.

How often does a boiler need CSD-1 testing?

That depends on the boiler and on the requirements that apply to your facility, so confirm it with your insurance carrier or the authority having jurisdiction. We offer annual CSD-1 testing as a single visit or as part of a preventive maintenance plan.

Can you help us get ready for a boiler inspection?

Yes. Our confined-space-qualified technicians open, clean, and prepare the pressure vessel for inspection, and handle tube, refractory, and ASME code repairs when needed.

Will we get documentation?

Combustion analysis comes with printed results you keep. Facilities on a maintenance plan also get a written service report after every visit, including combustion readings, so there is a running record for inspectors and insurers.

Can CSD-1 testing be part of a maintenance contract?

Yes. CSD-1 testing is one of the services a preventive maintenance plan can include, and every plan we build is custom to your equipment. Because plans are custom, we don’t publish fixed prices.

Schedule CSD-1 testing

Tell us about your boilers

Send the boiler make, model, and count, your site location, and when your testing is due. For a boiler that’s down right now, call, we answer 24/7.

Call 248-589-8220
Call Now Get a Quote